      Welcome~Shenzhen Santak UPS power supply Co., Ltd.
      Language: 中文版 ∷  英文版

      C1KVA-3KVA Rack

      • Frame type C1-3KR Santak UPS power supply
      • Frame type C1-3KR Santak UPS power supply
      Frame type C1-3KR Santak UPS power supply Frame type C1-3KR Santak UPS power supply

      Frame type C1-3KR Santak UPS power supply

      • Model: C1KR, C1KRS, C2KR, C2KRS, C3KR, C3KRS, C6KR, C6KRS
      • Capacity: 1kVA/0.7kW, 1kVA/0.7kW, 2kVA/1.4kW, 2kVA/1.4kW, 3kVA/2.1kW, 3kVA/2.1kW, 6kVA/4.2kW, 6kVA/4.2kW
      • Input voltage: 115~300VAC, 176~276VAC
      • Output voltage: 200VAC
      • Product description: The Santak frame type UPS power supply castle series Rack 1KVA to 6KVA UPS, using the dual conversion pure online architecture, is a reliable architecture design to effectively solve all power problem
      • INQUIRY
      Santak UPS power supply features:


      正弦波输出

      Sine Wave Output

      无论在市电模式或电池模式,均可输出低失真度的正弦波电源,为用户的负载设备供可靠的电源保障。

      No matter in the power mode or battery mode, the sine wave power supply with low distortion can be exported to provide reliable power supply for the load equipment of the user.


      零转换时间

      Zero conversion time

      当市电停电或复电时,UPS在市电模式与电池模式之间的切换是完全没有转换时间的,有效保证了负载运行的可靠性。

      When the electricity is blackout or reelectric, the switching between the UPS mode and the battery mode is completely without the conversion time, which effectively ensures the reliability of the load operation.


      输入零火线侦测功能

      Input zero fire line detection function

      山特Rack UPS 1K~3K(S)具备零火线反接侦测功能。,避免UPS市电输入零火线反接。

      Santak Rack UPS 1K~3K (S) has the function of zero line reverse connection detection. To avoid UPS city electric input zero fire line back connection.


      旁路输出人性化

      Humanization of by-pass output

      为 了避免山特用户让UPS工作于BYPASS MODE不开机使用,造成市电中断,UPS与设备均异常关机。山特Rack UPS 1K~3K(S)输入正常市电,默认无旁路输出。必须开机,才会有正常逆变输出。但可以通过山特网站上的WinPower2000软件来更改配置为“上市 电有旁路输出”。

      In order to prevent Santak users from letting UPS operate at BYPASS MODE, the power failure is interrupted and UPS and equipment are shut down. Santak Rack UPS 1K~3K (S) input normal power, default no bypass output. It is necessary to open the machine to have normal inverter output. But it can be changed through Santak's WinPower2000 software to "bypass output".


      TVSS功能

      TVSS function

      即TRANSIENT VOLTAGE SURGE SUPPRESS突波电压?;すδ?。在Rack UPS上被用于FAX、TELEPHONE、MODEM、网络等转换?;すδ?。

      That is, TRANSIENT VOLTAGE SURGE SUPPRESS surge protection function. On Rack UPS, it is used for conversion protection functions such as FAX, TELEPHONE, MODEM and network.


      输入功因修正

      Input power factor correction

      Rack UPS具备输入功因修正功能,在满载情况下,输入功因可以达到0.95以上,使用户的电网环境不会受到污染。

      Rack UPS has the function of correction because of input function. Under full load condition, input power can reach more than 0.95, so that the power grid environment of users will not be polluted.


      直流启动

      DC start

      在市电停电状态下,若需要使用Rack UPS启动计算机或其它负载设备,Rack UPS可以直接以电池进行直流开机,使Rack UPS的使用更加方便、可靠。

      In the state of power outage, if you need to use Rack UPS to start the computer or other load equipment, Rack UPS can direct direct current with battery, so that the use of Rack UPS is more convenient and reliable.


      旁路?;?

      Bypass Protection

      旁路供电功能使Rack UPS的应急处理能力大大加强,同时在用户的负载设备对电源具有特殊要求时,如电压不能过高,Rack UPS提供旁路供电电压过高?;?,使用户的负载设备免于高压危险。

      The bypass power supply has greatly enhanced the emergency handling capacity of the Rack UPS. At the same time, when the user's load equipment has special requirements on the power supply, such as the voltage cannot be too high, the Rack UPS provides the overvoltage protection of the bypass power supply, and the user's load equipment is free from the danger of high voltage.


      自动启动功能

      Auto start function

      当市电异常,进入电池模式供电直到截止,Rack UPS将关机,当市电恢复正常时,Rack UPS又会自动启动开机,恢复正常供电,无需用户逐一开机。

      When the electricity is abnormal, when the battery mode is supplied to the power supply, the Rack UPS will turn off, and when the city power is restored to normal, the Rack UPS will automatically start the boot to restore the normal power supply without the need for the user to turn on the machine one by one.


      长效型供电设计

      Long effect power supply design

      Rack UPS全面提供长效机供用户选择。配置合适的电池组,可以使用户放电使用时间可达8小时左右,以满足不同电网环境的要求。

      Rack UPS provides a full - effect machine for user selection. A suitable battery pack can be used to discharge the user for about 8 hours to meet the requirements of different power grid environments.


      长效机强大充电能力

      The powerful charging capability of the long effect machine

      Rack UPS长效机除了放电时间延长,电池回充能力也很强,可以提供约4~9A的初始充电电流。

      In addition to prolonged discharge time, the Rack UPS long efficiency machine can also provide strong recharge capability, which can provide an initial charging current of about 4 ~ 9A.


      自我检查功能

      Self-examination function

      Rack UPS可以进行模拟断电的情况,进入电池模式供电,此功能既可通过面板上的自检按键随时执行,也可以配合山特监控软件,按定期或不定期方式进行。

      Rack UPS can simulate power failure, enter the battery mode power supply, this function can be executed at any time through the self check key on the panel, and can also be carried out in regular or irregular mode with Santak monitoring software.


      强力抗干扰

      Strong anti-interference

      针对电磁干扰与射频干扰,Rack UPS依循国际标准EN50091-2和IEC61000-4系列标准设计,有效提高了UPS使用的安全性与可靠性。

      In view of electromagnetic interference and radio frequency interference, Rack UPS is designed according to the standard of international standard en500, 500, 9, 2 and IEC61000-4, which effectively improves the security and reliability of the use of UPS.


      可搭配发电机使用

      Can be used with generator

      宽广的输入电压与频率范围,使Rack UPS可以与主要品牌发电机搭配使用,使用时间更加延长,同时有效去除了发电机所产生的不良的电力,为负载提供纯净、安全、稳定的电源。

      The wide input voltage and frequency range, so that the Rack UPS can be used with the main brand generator, the use of longer time, while effectively removing the generator produced by the bad power, providing a pure, safe, stable power supply for the load.


      可接感性负载

      Inductive load

      Rack UPS可接感性负载(pf=0.8)??突缬衅渌厥庑枨?,可直接接洽山特公司。

      Rack UPS can be connected to the inductive load (pf=0.8). If there are other special needs, customers can directly contact Santak.


      网站免费下载WinPower2000监控软件

      Free download of WinPower2000 monitoring software by web site

      为了使用户对UPS的管理更加便捷、有效,在山特网站上可免费下载WinPower2000网络版监控软件,实现智能化管理。

      In order to enable users to manage UPS more conveniently and effectively, the WinPower2000 network version monitoring software can be downloaded freely on Santak website to realize intelligent management.


      配备Intelligent Slot 智能插槽

      Equipped with Intelligent Slot smart slot

      Rack UPS配备一个Intelligent Slot智能插槽,用户可以选购山特AS400卡,以提供IBM AS400标准通讯信号,用户利用AS400界面来作Remote Display,包含声音报警及灯光显示?;蜓」荷教豔ebPower智能监控卡,通过Internet国际互联网进行全球化管理,或者通过SNMP网 管,实现集中监控及远程监控等功能。

      Rack UPS is equipped with a Intelligent Slot smart slot, users can choose Santak AS400 card to provide IBM AS400 standard communication signals, users use the AS400 interface for Remote Display, including sound alarm and lighting display. Or select and buy Santak WebPower intelligent monitoring card, through the Internet international Internet for globalization management, or through SNMP network management, to achieve centralized monitoring and remote monitoring and other functions.


      配置标准电池包

      Configuring standard battery packs

      Rack UPS配置了主机相同尺寸的标准电池包(供客户选择)。除要求C2KR、C3KR、C6KR标机配置一组标准电池包外,还要求C1KRS、C6KRS长效 机配置2组以上标准电池包,及C2KRS、C3KRS长效机配置3组以上标准电池包。标准电池包内电池均采用高品质的原厂松下蓄电池,以良好的电池质量, 保证UPS使用安全性与可靠性。

      Rack UPS configuring the standard battery pack of the same size of the host (for customers to choose). In addition to the requirements of C2KR, C3KR, and C6KR machines to configure a set of standard battery packages, 2 or more standard battery packages are required to be configured for C1KRS and C6KRS long effect machines, and 3 or more standard battery packages are configured with C2KRS and C3KRS long effect machines. The battery in standard battery pack adopts high quality original Matsushita Battery, with good battery quality, ensuring the safety and reliability of UPS.


      规格参数表:

      Specification parameter table:


      型号

      Model

      C1KR,C1KRS,C2KR,C2KRS,C3KR,C3KRS,C6KR,C6KRS

      C1KR, C1KRS, C2KR, C2KRS, C3KR, C3KRS, C6KR, C6KRS


      额定功率

      Rated power

      1kVA/0.7kW,1kVA/0.7kW,2kVA/1.4kW,2kVA/1.4kW,3kVA/2.1kW,3kVA/2.1kW,6kVA/4.2kW,6kVA/4.2kW

      1kVA/0.7kW, 1kVA/0.7kW, 2kVA/1.4kW, 2kVA/1.4kW, 3kVA/2.1kW, 3kVA/2.1kW, 6kVA/4.2kW, 6kVA/4.2kW


      输入相位

      Input phase

      单相

      Single-phase


      额定输入

      Rated input

      115~300VAC,176~276VAC

      115~300VAC, 176~276VAC


      额定输出

      Rated output

      200VAC

      200VAC


      输入频率

      Input frequency

      (40-60)Hz( 可调整 ),46-54Hz

      (40-60) Hz (adjustable), 46-54Hz


      输入功率因数

      Input power factor

      ≥ 0.97,≥ 0.98

      More than 0.97, more than 0.98


      频率(Hz)

      Frequency (Hz)

      50

      Fifty

      输出电压精度

      Output voltage precision

      ±2%,±1%

      + 2%, + 1%


      输出频率精度

      Output frequency accuracy

      跟随市电 ( 市电模式下工作 ),50Hz±0.2Hz( 电池模式下工作 ),50(1±0.1%)Hz( 电池模式下工作 )

      Follow the electricity (electricity mode), 50Hz + 0.2Hz (battery mode), 50 (1 + 0.1%) Hz (battery mode).


      输出功率因数

      Output power factor

      0.7 滞后

      0.7 lag


      输出电压失真度

      Output voltage distortion

      带线性负载 <4% 带非线性负载 <7%,带线性负载 <2% 带非线性负载 <6%

      Linear load <4% with nonlinear load <7%, linear load <2% with nonlinear load <6%


      输出过载能力

      Output overload capacity


      负载大于110%,工作30秒转旁路;负

      Load more than 110%, work 30 seconds to bypass; negative